Industrial Hypochlorous Acid Water Generator Manufacturing Facility UJDI Machinery
On-Site Membrane Electrolysis

Industrial Hypochlorous Acid Water Generator: The Engineering & Procurement Guide

High-capacity HOCl production plants delivering 50–1,000 ppm available free chlorine with ultra-precise pH control for global food processing, agriculture, and water treatment.

Precision Stainless Steel Electrolysis Cell Assembly UJDI Machinery
80x More Effective Than Sodium Hypochlorite

Eco-Friendly, Residue-Free Industrial Sanitization

Eliminate chemical transport hazards with on-demand, cost-effective HOCl generation engineered to international standards.

CE Certified Water Treatment and HOCl Electrolysis Assembly
CE Certified · Intertek Assessed

Custom Engineered Systems by UJDI Machinery

Turnkey installation, automated ORP/pH online monitoring, and full food-grade SUS316L fluid contact construction.

0+
Years of Liquid Engineering
Intertek
On-site Assessed Supplier
0+
Years Global Export Proven
5.0/5
Verified Quality Rating
Hypochlorous Acid Water Generator Assembly Workshop UJDI Machinery
99.99%Pathogen Reduction
Technical Mastery

The Electrochemistry of Hypochlorous Acid Water Generators

As global supply chains shift toward sustainable, chemical-free disinfection, the Hypochlorous Acid Water Generator has emerged as the definitive solution for high-level sanitization. Hypochlorous acid (HOCl) is a weak acid naturally synthesized by mammalian white blood cells (neutrophils) to eliminate biological pathogens. When produced via targeted electrochemical activation (ECA), HOCl demonstrates an antimicrobial efficacy up to 80 times greater than traditional sodium hypochlorite (bleach) at equivalent concentrations of available free chlorine (FAC).

Zhangjiagang UJDI Machinery Co., Ltd. designs and manufactures advanced industrial HOCl generators utilizing state-of-the-art membrane electrolysis. By passing a softened saline solution (NaCl + H₂O) through an electrolyzer equipped with Ruthenium-Iridium (Ru-Ir) coated titanium electrodes and a selective ion-exchange membrane, our systems continuously yield pure HOCl at controlled pH levels (5.0–6.5) and Oxidation-Reduction Potentials (ORP) exceeding +950 mV.

  • Precision pH equilibrium (5.0 to 6.5) prevents gas off-gassing
  • High ORP (>950 mV) disrupts bacterial lipid membranes in seconds
  • Zero toxic residues; breaks down into mild saline water
  • Non-corrosive to food-contact surfaces & stainless machinery
Product Lineup

Industrial HOCl Water Generator Series

Engineered for continuous heavy-duty operational demands across industrial food processing plants, agricultural facilities, municipal water systems, and commercial beverage plants.

UJDI-HOCl-500 Compact Hypochlorous Acid Water Generator 500 L/h Output CE

UJDI-HOCl-500 Commercial Unit

  • FAC Concentration50 - 300 ppm
  • pH Range5.2 - 6.5 Adjustable
  • Cell TypeMembrane Electrolysis
  • Anode MaterialRu-Ir Coated Titanium
Get Catalog
UJDI-HOCl-2000 Industrial Hypochlorous Acid Generator System 2,000 L/h Output CE

UJDI-HOCl-2000 Industrial Line

  • FAC Concentration100 - 500 ppm
  • pH Range5.0 - 6.2 Precision Controlled
  • AutomationPLC + Touchscreen Interface
  • ORP Rating+950 mV to +1100 mV
Get Catalog
UJDI-HOCl-5000 High Capacity Electrolyzed Water System 5,000 L/h Output CE

UJDI-HOCl-5000 Modular Plant

  • FAC Concentration200 - 800 ppm
  • Fluid ContactSUS316L & Titanium
  • Water FeedIntegrated RO Pre-treatment
  • MonitoringReal-time Online Titration
Get Catalog
UJDI-HOCl-10000 Heavy Duty Hypochlorous Acid Plant 10,000 L/h Output CE

UJDI-HOCl-10000 Skid System

  • FAC ConcentrationUp to 1,000 ppm
  • Power Efficiency< 4.5 kWh / kg Chlorine
  • Cell Longevity> 15,000 Continuous Hours
  • ComplianceCE, ISO, Intertek Assessed
Get Catalog
Engineering Matrix

Technical Specifications & Operational Benchmarks

Compare performance parameters across our primary Hypochlorous Acid Water Generator models to determine optimal plant sizing for your facility.

Model Designation Hourly Solution Capacity Available Free Chlorine (FAC) pH Equilibrium Control Electrical Consumption Target Industrial Application
UJDI-HOCl-500 500 Liters / Hour 50 – 300 mg/L (ppm) 5.2 – 6.5 (±0.1 pH) 1.8 kW / Hour Commercial kitchens, healthcare facilities, greenhouse spray
UJDI-HOCl-2000 2,000 Liters / Hour 100 – 500 mg/L (ppm) 5.0 – 6.2 (±0.1 pH) 5.5 kW / Hour Food processing produce washing, dairy sanitation, CIP loops
UJDI-HOCl-5000 5,000 Liters / Hour 200 – 800 mg/L (ppm) 5.0 – 6.0 (±0.05 pH) 12.5 kW / Hour Poultry processing, slaughterhouses, large agricultural rinse
UJDI-HOCl-10000 10,000 Liters / Hour 200 – 1,000 mg/L (ppm) 5.0 – 6.0 (±0.05 pH) 24.0 kW / Hour Municipal water treatment, central disinfection hubs, industrial effluent

*Note: Operating capacity and energy consumption depend on feedwater total dissolved solids (TDS), ambient temperature, and target FAC concentration. Custom high-tonnage skids are available upon request from Zhangjiagang UJDI Machinery Co., Ltd.

Versatile Applications

Industrial Sectors Powered by UJDI HOCl Technology

Because HOCl is non-toxic, non-irritating to skin, and food-safe, it replaces traditional aggressive chemical sanitizers across diverse sectors.

Fresh Produce Processing

Post-harvest washing without leaving chemical residue; extends produce shelf life while suppressing E. coli and Salmonella.

Beverage & Bottling Lines

Rinsing PET bottles, aluminum cans, and internal CIP stainless pipelines to maintain sterile aseptic filling environments.

Livestock & Agriculture

Aerial fogging for poultry housing, water line bio-film removal, and pathogen control in hydroponic feed loops.

Healthcare & Medical

Cold-sterilization of surgical instruments, environmental fogging, and surface disinfection in clinical zones.

Manufacturing Authority

Why Global Engineering Buyers Partner with UJDI Machinery

Rooted in Zhangjiagang, Jiangsu — China's premier hub for liquid treatment and packaging machinery — Zhangjiagang UJDI Machinery Co., Ltd. delivers full-lifecycle engineering support.

13+ Years of Engineering Specialization

Over a decade of dedicated expertise designing water treatment systems, electrolysis units, and fluid filling networks for international clients across 50+ countries.

Intertek On-Site Assessed & CE Certified

Our manufacturing plant undergoes rigorous physical audits by Intertek. All equipment carries verified CE safety certifications and ISO quality management compliance.

Food-Grade Material Rigor

All liquid contact components are fabricated strictly from certified SUS304/SUS316L stainless steel, high-purity titanium, and chemical-grade fluoropolymers.

Buyer Knowledge Base

Frequently Asked Questions on Industrial HOCl Generators

Critical operational, chemistry, and procurement guidance designed for industrial engineers and technical buyers.

What is the ideal pH and concentration range for an industrial Hypochlorous Acid Water Generator?

The optimal equilibrium for Hypochlorous Acid (HOCl) efficacy occurs within a pH range of 5.0 to 6.5. Within this tight neutral-to-slightly-acidic window, over 95% of available free chlorine (FAC) exists in the active HOCl form rather than hypochlorite ions (OCl⁻, dominant in alkaline bleach) or dissolved chlorine gas (Cl₂, which off-gasses below pH 4.0). Industrial units manufactured by Zhangjiagang UJDI Machinery Co., Ltd. feature dynamic PLC-controlled acid/salt dosing to maintain exact target pH even during fluctuations in raw feedwater alkalinity.

How does membrane electrolysis compare to non-membrane electrolysis in HOCl generation?

Membrane electrolysis employs a specialized ion-exchange diaphragm to separate the anode and cathode chambers. This configuration produces high-purity, single-stream HOCl at pH 5.0–6.0 with negligible byproduct salts. Non-membrane (single-chamber) systems electrolytic cell solutions combine anodic and cathodic outputs, producing alkaline electrolyzed water mixed with sodium hypochlorite. Non-membrane fluids contain high residual sodium chloride (NaCl) levels, increasing the risk of equipment surface corrosion and reducing fluid stability during storage.

What is the operational cost per ton of HOCl solution produced on-site?

On-site HOCl generation delivers immense cost savings compared to purchasing packaged chemical disinfectants. Producing 1 metric ton (1,000 liters) of 200 ppm HOCl water requires approximately 1.5 kg to 2.5 kg of food-grade salt (NaCl) and approximately 3.0 to 4.5 kWh of electricity. Depending on local utility tariffs, the direct variable cost ranges between $0.004 and $0.009 per liter, yielding ROI payback periods typically under 8 to 12 months for commercial processing plants.

What materials are used for key electrolytic cell components to ensure longevity?

The internal electrolyzer operates in a intensely oxidative environment. UJDI Machinery utilizes high-grade Titanium (Grade 1) anodes substrate coated with an electrochemically active Ruthenium-Iridium-Platinum nanocomposite layer. Internal cell housings are molded from solid PVDF (Polyvinylidene Fluoride) or machined PTFE. External piping and skid frames are constructed from SUS316L stainless steel to prevent localized atmospheric pitting.

What is the stability and shelf life of generated Hypochlorous Acid water?

When generated at correct pH (5.5) and stored in UV-shielded, airtight HDPE or glass containers, HOCl maintains effective antimicrobial potency (less than 10% degradation) for 6 to 12 months. However, exposure to direct sunlight (ultraviolet radiation), temperatures above 35°C, or organic particulate contact will accelerate decomposition into mild saline water. For optimal facility efficiency, UJDI Machinery recommends integrating on-demand generation directly into daily sanitation distribution headers.
Engineering Consultation

Request Your Turnkey HOCl System Proposal

Connect directly with our engineering team in Zhangjiagang. We provide comprehensive fluid sizing, electrical consumption calculations, and customized skid layouts.

info@ujdimachine.com

Technical Details to Accelerate Proposal Sizing:

  • Required HOCl Volume (Liters / Hour or Gallons / Day)
  • Target FAC Concentration (ppm) & Target Application
  • Feedwater Source (Municipal, Well Water, Reverse Osmosis)
  • Regional Electrical Voltage / Frequency Standard
Get Catalog